Hello all. Over the last 4 or 5 months, I have noticed my CHT's have been steadily rising and the spread from the hottest to the coolest is increasing as well. (Used to be 30 degrees, now it varies between 35 & 40) It is to the point where I can't fully close the cowl flaps. This hasn't been an issue for the last 250+ hours on the plane over the past year and a half. This is when I started running LOP. I have an M20K/231. Inner-cooler and 'automatic' wastegate & GAMI injectors. I took the first picture this morning while flying from Phoenix to San Diego. LOP, 12k, Cowl flaps in tow (Fully closed and CHT's go over 400) The second pic is almost a year ago to date. LOP, Cowl flaps closed, not sure altitude but probably pretty close to 12k. I know It was running about 45 degrees more LOP a year ago, but the CHT's are much cooler with the cowl flaps closed than they are now. What could/would have changed over the last year? (Compression check 2 weeks ago showed about same as annual in Nov. Any help would be appreciated!